Schneider A9D61820 Description
n
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO).
n
nIt is a 1P+N circuit breaker with 1 protected pole, 20A In rated current and C tripping curve.
n
nThe earth leakage protection class is A type with a sensitivity of 30mA.
n
nThe earth-leakage protection time delay is instantaneous.
n
nThe Icn rated short circuit breaking capacity is up to 6000A according 0 standard.
n
nIts unique Visitrip indicator reduces intervention time by showing the faulty circuit.
n
nIts Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
n
nIts fast closing mechanism independent of manual operation improves its service life.
n
nThis product is compliant with AS/NZS 61009.1 and IEC 61009-2-2 standards.
n
nIt has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles.
n
nThe Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC.
n
nThe Uimp rated impulse withstand voltage is 4kV.
n
nThe frequency is 50Hz. It is DIN rail mountable.
n
nThe width in 9mm pitches is 2. The product color is white (RAL9003).
n
nThe dimensions are (W) 18mm x (H) 110mm x (D) 77.5mm. The weight is 205g.
n
nIt has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure.
n
nThe operating temperature is from -15°C to 60°C.
n
nThe storage temperature is from -40°C to 85°C.
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
The Schneider A9D61820 is part of the Acti9 series, which includes a range of modular protection devices designed for electrical distribution systems in residential, commercial, and industrial applications. This specific model is a Residual Current Circuit Breaker with Overcurrent Protection (RCBO).
n
n
Schneider A9D61820 Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
n
Key Features:
n
n
n
Protection:
n
n
Combines the functions of a miniature circuit breaker (MCB) and a residual current device (RCD) in one unit.
n
Provides protection against overcurrents (overload and short-circuit) and earth leakage currents.
n
Enhances safety by protecting people against electric shocks and preventing electrical fires.
n
n
n
Current Rating:
n
n
Rated at 20A, making it suitable for a range of applications requiring this current rating.
n
n
n
Sensitivity:
n
n
Earth leakage sensitivity of 30mA, which is the standard for protecting against indirect contact and fire hazards.
n
n
n
Design:
n
n
Compact and modular design allows for efficient use of space in electrical distribution boards.
n
DIN rail mountable, making installation and integration with other modular devices straightforward.
n
n
n
Breaking Capacity:
n
n
Designed to handle specific breaking capacity, ensuring reliable operation in various electrical installations.
n
n
n
Indicators:
n
n
Includes visual indicators for operational status and trip status, facilitating quick identification of issues.
n
n
n
n
Applications:
n
n
n
Residential: Ideal for protecting household electrical circuits, including power outlets, lighting circuits, and appliances.
n
Commercial: Suitable for protecting electrical circuits in offices and commercial buildings.
n
Industrial: Applicable in light industrial settings for protecting machinery and control circuits from overcurrents and earth leakage.
n
n
Benefits:
n
n
n
Enhanced Safety: Provides comprehensive protection by combining overcurrent and earth leakage protection, reducing the risk of electric shocks and fires.
n
Space-Saving: The modular design ensures efficient use of space in electrical panels.
n
Ease of Maintenance: Visual indicators provide quick identification of operational status and faults, making maintenance and troubleshooting easier.
n
Reliability: Built with high-quality materials to ensure long-lasting performance and reliable protection.
n
n
Considerations:
n
n
n
Compatibility: Ensure the RCBO is compatible with the specific electrical system and load requirements of your installation.
n
Regular Testing: Periodically test the RCBO to ensure it is functioning correctly and providing necessary protection.
n
Professional Installation: It is recommended to have a qualified electrician install and maintain the RCBO for optimal performance and safety.
n
n
Specifications:
n
n
n
Model: Schneider A9D61820
n
Series: Acti9
n
Current Rating: 20A
n
Sensitivity: 30mA
n
Poles: Single-pole + Neutral (1P+N)
n
Breaking Capacity: As per manufacturer specifications
n
n
Schneider Electric’s Acti9 series is known for its high-quality and reliable electrical protection devices, and the A9D61820 RCBO is an excellent choice for ensuring the safety and efficiency of your electrical systems.
We ship to all 50 states, Washington DC. All orders are shipped with a UPS tracking number. Always free shipping for orders over US $200. During sale periods and promotions the delivery time may be longer than normal.
Return
Urna will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period), on presentation of the original till receipt at any store where the corresponding collection is available within the country of purchase.
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed.
Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
Help
Give us a shout if you have any other questions and/or concerns.