This ComPacT NSX100B is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications.
n
The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 80A rating thermal-magnetic trip unit (TMD).
n
TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection.
n
This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.
n
It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.
n
ComPacT NSX100B is part of Schneider Electric EcoStruxure Power architecture.
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
introduction
nSchneider Electric is renowned for its high-quality electrical and automation products. Understanding the specifications and features of their products is essential for anyone involved in electrical installations or maintenance. This article will provide an in-depth look at the Schneider C10B3TM080, detailing its features, specifications, applications, and more.
n
Understanding the Schneider C10B3TM080
nThe Schneider C10B3TM080 is a miniature circuit breaker (MCB) designed to provide reliable protection for electrical circuits. It is ideal for preventing damage caused by overloads and short circuits in both residential and commercial settings.
n
Basic Description
nThe Schneider C10B3TM080 is a three-pole, 10A circuit breaker with a B curve, meaning it trips between 3 to 5 times the rated current, making it suitable for residential and light commercial applications where inrush currents are not typically high.
n
Key Features
n
n
Three-Pole Protection: Offers comprehensive protection for three-phase electrical systems.
n
Compact Design: Saves space in electrical panels.
n
High Breaking Capacity: Ensures effective protection against electrical faults.
n
Easy Installation: Designed for quick and straightforward installation.
n
Durability: Built to last with high-quality materials.
n
n
Technical Specifications
n
Electrical Specifications
n
n
Rated Voltage: 400V AC
n
Rated Current: 10A
n
Breaking Capacity: 6kA according to IEC/EN 60898-1
n
Tripping Curve: Type B (3-5 times the rated current)
n
n
Mechanical Specifications
n
n
Dimensions: 81mm x 54mm x 70mm
n
Weight: 0.42 kg
n
Mounting: DIN rail
n
n
Design and Construction
nThe design and construction of the Schneider C10B3TM080 emphasize both durability and efficiency, ensuring reliable performance over its lifetime.
n
Materials Used
n
n
Housing: Fire-resistant plastic
n
Internal Components: High-grade copper and silver alloy
n
Terminals: Corrosion-resistant metal
n
n
Build Quality
nSchneider Electric adheres to rigorous manufacturing standards to ensure each unit meets high quality and safety standards. The C10B3TM080 is built to withstand regular use in various environments.
n
Installation and Setup
nProper installation is critical to ensure the effective performance of the Schneider C10B3TM080. Here’s a step-by-step guide to help you install it correctly.
n
Pre-Installation Requirements
n
n
Ensure the main power supply is turned off.
n
Verify that the electrical panel can accommodate the MCB.
n
Gather necessary tools and safety gear.
n
n
Step-by-Step Installation Guide
n
n
Turn Off Main Power: Ensure the main power supply is off to prevent accidents.
n
Mount the MCB: Secure the C10B3TM080 onto the DIN rail in the electrical panel.
n
Connect Wires: Attach the input and output wires to the respective terminals, ensuring tight connections.
n
Test the Installation: Restore power and test the MCB to ensure it functions correctly.
n
Finalize Installation: Secure any loose wires and close the panel.
n
n
Applications and Use Cases
nThe Schneider C10B3TM080 is versatile, making it suitable for various applications.
n
Industrial Applications
nWhile primarily designed for residential and light commercial use, it can also be used in small-scale industrial applications where the electrical load does not exceed its specifications.
n
Commercial Applications
nIn commercial settings, the C10B3TM080 provides reliable circuit protection, ensuring safety and preventing electrical fires.
n
Residential Applications
nHomeowners can use the C10B3TM080 to protect household circuits, ensuring the safety of electrical appliances and preventing potential hazards.
n
Safety Features
nSafety is a paramount concern for Schneider Electric, and the C10B3TM080 includes several built-in safety features.
n
Safety Standards Compliance
nThe C10B3TM080 complies with international safety standards, including IEC/EN 60898-1, ensuring it meets stringent safety requirements.
n
Built-In Safety Mechanisms
n
n
Overload Protection: Automatically trips to prevent overheating and potential fires.
n
Short Circuit Protection: Quickly isolates faults to prevent damage to the electrical system.
n
n
Maintenance and Troubleshooting
nRegular maintenance is essential to keep the Schneider C10B3TM080 in optimal condition.
n
Regular Maintenance Tips
n
n
Visual Inspection: Regularly check the MCB for signs of wear or damage.
n
Testing: Periodically test the MCB to ensure it operates correctly.
n
Cleaning: Keep the MCB and surrounding area clean and free of dust.
We ship to all 50 states, Washington DC. All orders are shipped with a UPS tracking number. Always free shipping for orders over US $200. During sale periods and promotions the delivery time may be longer than normal.
Return
Urna will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period), on presentation of the original till receipt at any store where the corresponding collection is available within the country of purchase.
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed.
Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
Help
Give us a shout if you have any other questions and/or concerns.