Schneider C160N420FM | Circuit breaker, ComPacT NS1600N, 50kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1600A

Schneider Electric
Availability:

Out of stock


Schneider C160N420FM | Circuit breaker, ComPacT NS1600N, 50kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1600A

ComPacT NS is a range of circuit breakers for built-in power & energy metering

The solution covers ratings from 630 A to 3200 A
MicroLogic electronic control unit provides electrical measurement and analysis functions
ComPacT NS offers an optimized range of auxiliaries and accessories, field installable
Flexible installation, in any position, in a switchboard or wall-mounted

Compare

Schneider C160N420FM | Circuit breaker, ComPacT NS1600N, 50kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1600A

Product: Schneider C160N420FM

The C160N420FM is a high-capacity molded case circuit breaker (MCCB) from Schneider Electric’s ComPacT NS1600N series. It is engineered for reliable protection in large-scale industrial and commercial power distribution systems, offering performance and safety for high-current applications.

Detailed Breakdown:

1. Series & Model:

  • ComPacT NS1600N

  • The “1600” indicates a frame size of 1600A, which defines the maximum rated current the breaker is built to handle.

  • The “N” version is a standard performance model with compact construction and high reliability.

2. Rated Current:

  • 1600 Amps (A)

  • This is the maximum continuous current the breaker can handle without tripping.

  • Designed for heavy-duty circuits like main incomers, large machinery, or generator outputs.

3. Breaking Capacity:

  • 50 kA at 415 VAC

  • The breaker can interrupt a short-circuit current up to 50,000 amps safely.

  • Suitable for use in systems with high fault current potential (e.g., near transformers or large motors).

4. Number of Poles:

  • 4 Poles (4P)

  • Protects three phases and neutral conductor.

  • Ideal for systems requiring complete disconnection, including unbalanced loads and neutral protection.

5. Mounting Type:

  • Fixed

  • Installed permanently into a switchboard or panel.

  • Not withdrawable, which means manual disconnection is needed during servicing or replacement.

6. Operation Method:

  • Manually Operated

  • Operated by hand, using a toggle or rotary handle.

  • No motorized mechanism — remote control is not available in this version.

7. Trip Unit / Protection Unit:

  • MicroLogic 2.0

  • A basic electronic trip unit that provides:

    • Long-time delay protection (for overloads)

    • Short-time delay protection (for short circuits)

  • Adjustable protection settings to match system requirements.

  • Does not include advanced metering or communication features.

Typical Applications:

  • Main circuit breaker for large distribution panels

  • Generator or transformer protection

  • Industrial power systems with high loads and neutral requirements

  • Large commercial buildings, factories, or critical infrastructure

Brands

Main
Range ComPacT
Product name ComPacT NS new generation
Range of product ComPacT NS630b…1600 new generation
Product or component type Circuit breaker
Device application Distribution
Number of poles 4P
Protected poles description 4D
Neutral position Left
[In] rated current 1600 A at 50 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category B
Breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code N 50 kA 415 V AC
Trip unit name MicroLogic 2.0
Trip unit technology Electronic
Trip unit protection functions LI
Control type Manually operated
Mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity 37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current 19.2 kA 1 s conforming to IEC 60947-2
Mechanical durability 10000 cycles
Electrical durability 1000 cycles at 690 V In
2000 cycles at 690 V In/2
2000 cycles at 440 V In
5000 cycles at 440 V In/2
Power losses 74 W
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 70 mm
Protection type L : for overload protection (long time)
I : for instantaneous short-circuit protection
Trip unit rating 1600 A at 50 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 0.4…1 x In
Long-time protection delay adjustment type tr Adjustable 9 settings
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
Thermal memory 20 mn
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5…10 x Ir
Earth-leakage protection Without
Neutral protection setting No protection (3D)
0.5 x Ir (3D + N/2)
1 x Ir (4D)
Zone selective interlocking ZSI Without
Auxiliary contact composition 1 NO/NC
Local signalling 4 LEDs (red) for fault indication
1 LED (yellow) for overload
Width (W) 280 mm
Height (H) 327 mm
Depth (D) 147 mm
Net weight 18 kg
Environment
Standards EN/IEC 60947-2
Product certifications IECEE CB Scheme
Overvoltage category III
Electrical shock protection class Class II on front face
Pollution degree 3 conforming to IEC 60947
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 37.000 cm
Package 1 Width 38.000 cm
Package 1 Length 30.000 cm
Package 1 Weight 16.966 kg

date sheet

https://www.se.com/id/en/product/download-pdf/C160N420FM?filename=Schneider+Electric_ComPacT-NS-new-generation_C160N420FM.pdf

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C160N420FM | Circuit breaker, ComPacT NS1600N, 50kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1600A”

There are no reviews yet.

SHOPPING CART

close

Select at least 2 products
to compare